Beckman System Gold High Performance Liquid Chromatograph OverviewBeckman System Gold (R) HPLC systems incorporate the latest technological advances in hardware design. The solvent delivery modules are built with the digitally. Hi Maria, I know that the Beckman HPLCs used a control board known as a Gold Board to control their systems. LP-chrom is capable to control Beckman System Gold HPLC devices. It makes it real alternative for original Karat 32 software. It is able to fully control pumps: with digital interface (116,125, 126 and 128) and with voltage control (110B and 114M) and UV 166 detector. Beckman Coulter Gold HPLC System Beckman GoldĀ® HPLC systems incorporate the latest technological advances in hardware design. The solvent delivery modules are built with the digitally controlled rapid refill pump design with automatic compressibility compensation that has received multiple patents.
Tips for buying HPLC Parts
Beckman Coulter System Gold Hplc Manual
- Based on HPLC user preference, the sample injector can be either fixed or variable loop.
- To meet the needs of most HPLC chromatograph analytical testing requirements, an injector capable of injecting a sample volume of 0.5 to 50 uL is needed.
- An automatic HPLC sample injector is preferable because it is generally more precise and provides continuous injection without user intervention for batch processing of samples.
- A manual sample chromatography system injector may be suitable for small testing volumes
- Stainless steel or any other material that can withstand pressures of up to 10,000 psi should be constructing the HPLC chromatograph column. The column should be at least 10-150 cm long with an internal diameter from 2-5 mm.
- To maximize efficiency of the HPLC, the particle size should be uniform and either spherical or irregularly shaped.
- A chemical resistant material, such as stainless steel or Teflon, should be constructing the high-performance liquid chromatography system pump.
- HPLC chromatograph pumps should be able to deliver solvents at pressures ranging from 500 to 5,000 psi.
- The waived tests category requires little or no training or experience to perform. These tests do not require elaborate quality control, and they are less likely to produce inaccurate results.
- Most clinical laboratory tests are included in the moderate complexity category, including automated urine, blood, and chemistry analyses. Tests and HPLC analyzers in this group require a limited amount of sample and reagent preparation, as well as limited operator intervention during the analytical process.